OpenSTAAD V8i
Returns output unit for sectional inertia used by the GUI as a string and is set in the Options dialog box.
Where:
A string containing the output unit for sectional inertia.
This is not a conversion unit used in accessing data through OpenSTAAD. Values are always returned in the units of the base unit system, which can be obtained using the GetBaseUnit
function.
Dim strOutputUnitForSectInertia as String
'Get the application object --
'Get Output Unit For Sectional Inertia
strOutputUnitForSectInertia = objOpenSTAAD.Output.GetOutputUnitForSectInertia